X ray optics cooling

The thermal problem is one of the most severe to be solved for an efficient use of the high brilliance X-ray source since mirrors loose their optical performances under heat load due to surface distorsion.
IRELEC has developed an optimised cooling system for high heat load X-ray mirror. This cooling system is validated by thermo-mechanical FEM simulation and is compatible with bending system.

Definition and realisation of cooling system for mirrors or crystals have been carried out for :
ESRF : CRG-FAME beamline
CAMD : XRLM1 beamline
ANKA : SUL beamline
SSLS : SINS beamline


Files :